Test Item | Equipment Model | Test Standard | Key Parameters and Criteria |
---|---|---|---|
Vertical Burning Test | Atlas HVUL-94 Vertical Burn Tester | UL 94 |
-V-0 Rating: Self-extinguishing within 10s, No Dripping - Burn Length ≤80mm |
Horizontal Burning Test | GB/T 2408 Horizontal Burn Tester | GB/T 2408 | Burn Rate ≤75 mm/min (HB Rating) |
Limiting Oxygen Index (LOI) | Fire Testing Technology LOI100 | ASTM D2863 | LOI ≥32% (Self-Extinguishing Material) |
Cone Calorimeter Test | FTT Cone Calorimeter | ISO 56601 |
- Peak Heat Release Rate ≤100 kW/m² - Total Smoke Release ≤200 m²/kg |
Smoke Density Test | NBS Smoke Density Chamber (FTT SDC) | ASTM E662 | Maximum Specific Optical Density (Ds max) ≤200 |
Toxic Gas Analysis | Thermo Fisher iCAN 9000 Gas Analysis System | EN 45545-2 | CO ≤1000 ppm, HCN ≤150 ppm |
- Sample Size: 125 mm × 13 mm × Thickness
- Flame Height: 20 mm (Methane Flame)
- Ignition Time: Two 10-second applications
Rating | Self-Extinguishing Time (Single Ignition) | Burn Length | Dripping |
---|---|---|---|
V0 | ≤10 seconds | ≤80 mm | None |
V1 | ≤30 seconds | ≤125 mm | None |
- Principle: Measures the minimum oxygen concentration required to sustain combustion in a nitrogen-oxygen mixture.
- LOI ≥28%: Flame-Retardant Material
- LOI ≥32%: Self-Extinguishing Material (DEEPROTECT® Standard)
- Radiant Power: 50 kW/m²
- Sample Size: 100 mm × 100 mm × Thickness
Parameter | DEEPROTECT® Standard |
---|---|
Peak Heat Release Rate (pHRR) | ≤50 kW/m² |
Total Heat Release (THR) | ≤10 MJ/m² |
Smoke Production Rate (SPR) | ≤0.1 m²/s |
- Insulation Performance: Post-combustion insulation resistance ≥10⁹ Ω·cm (Test Equipment: Megger MIT1525).
- Soundproofing Performance: Post-combustion NRC reduction ≤10% (Test Equipment: Bruel & Kjaer 2250).
- Waterproof Performance: Post-combustion hydrostatic pressure ≥4000 Pa (Test Equipment: SDL Atlas Hydrostatic Tester).
Equipment Name | Brand/Model | Application |
---|---|---|
Vertical Burn Tester | Atlas HVUL-94 | UL 94 Certification |
Cone Calorimeter | Fire Testing Technology FTT Calorimeter | Heat Release and Smoke Analysis |
Toxic Gas Analysis System | Thermo Fisher iCAN 9000 | Combustion Gas Toxicity Testing |
Oxygen Index Tester | FTT LOI100 | Material Self-Extinguishing Assessment |
- Flame Retardancy: UL 94 V-0, EN 13501-1 Class A, GB 8624 Class A
- Toxicity Control: EN 45545-2 (Rail Transit), NFPA 130 (Subway Fire Safety)
- Comprehensive Certifications: DIN 4102 (German Building Fire Standards), BS 6853 (British Railway Standards)
- Pre-Treatment: Condition samples at 23°C/50% RH for 48 hours.
- Vertical Burning Test: Record self-extinguishing time and dripping.
- Cone Calorimeter Analysis: Measure heat release and smoke data.
- Toxic Gas Detection: Analyze concentrations of CO, HCN, etc.
- Post-Test Performance Verification: Validate insulation, soundproofing, and waterproofing after combustion.
Through rigorous testing, DEEPROTECT™ fireproof fabrics ensure fourfold protection in fires: flame retardancy, low smoke, non-toxicity, and stable performance.
For product-specific testing or technical guidance, contact the DEEPROTECT™ Technical Team!
2nd Floor, No. 2 Standard Workshop, Hengke Industrial Park Phase I,Ganzhou Economy and Technology Development Zone, Ganzhou City, Jiangxi Province, P.R. China